A Power Quality Improved by using Fuzzy Logic Controller in Bridgeless Converter Based Computer Power Supply

Authors

  • Kathi Sivapriya  M.TECH STUDENT / Dept. of Electrical & Electronic Engineering (EPS): MJR College of engineering &Technology , Piler A.P. India
  • G. Seenaiah  Assistant Professor. Dept. of Electrical & Electronics Engineering: MJR College of engineering &Technology, Piler A.P. India
  • V. Sunil Kumar Reddy  HOD, Dept. of Electrical & Electronics Engineering: MJR College of engineering &Technology, Piler A.P. India

Keywords:

Bridgeless converter; PFC; input current; computer power supply; power quality

Abstract

In this paper Poor power quality, direct dynamic response, high contraption extend, consonant rich, incidentally thick, peaky, significant issues current are the huge issues which are sometimes experienced in conventional Switched Mode Power supplies (SMPSs) used as a piece of PCs. To diminish these issues, it is proposed here to use a non-separated bridgeless buck-support single-ended primary-inductor converter (SEPIC) in discontinuous conduction mode (DCM) at the front end of a SMPS. The bridgeless SEPIC at the front end gives unequivocally controlled output dc voltage even under progressive data voltage and load varieties. The output of the front end converter is associated with a half system dc-dc converter for withdrawal and besides to acquire particular dc voltage levels at the load end that are required in a PC. Controlling a lone output voltage can coordinate the different dc output voltages also

References

  1.  D. O. Koval and C. Carter, “Power quality      characteristics of computer loads,” IEEE Trans.on Industry Applications, vol. 33, no. 3, pp. 613- 621, May/June1997.
  2. Abraham I. Pressman, Keith Billings and Taylor Morey, “Switching Power Supply Design,” 3rd ed., McGraw Hill, New York, 2009.
  3. B. Singh, B.N. Singh, A. Chandra, K. Al-Haddad, A. Pandey and D.P. Kothari, “A review of single-phase improved power quality AC-DC converters” IEEE Trans. on Industrial Electronics, vol.50, no.5, pp.962- 981, Oct. 2003.
  4. K. Mino, H. Matsumoto, Y. Nemoto, S. Fujita, D. Kawasaki, Ryuji Yamada, and N. Tawada, “A front-end converter with high reliability and high efficiency,” in IEEE Conf. on Energy Conversion Congress and Exposition (ECCE),2010, pp. 3216-3223.
  5. Jih-Sheng Lai, D. Hurst and T. Key, “Switch-mode supply power factor improvement via harmonic elimination methods,” in 6th Annual IEEE Proc. on Applied Power Electronics Conference and Exposition, APEC’91, 1991, pp. 415-422.

Downloads

Published

2017-10-31

Issue

Section

Research Articles

How to Cite

[1]
Kathi Sivapriya, G. Seenaiah, V. Sunil Kumar Reddy, " A Power Quality Improved by using Fuzzy Logic Controller in Bridgeless Converter Based Computer Power Supply , IInternational Journal of Scientific Research in Computer Science, Engineering and Information Technology(IJSRCSEIT), ISSN : 2456-3307, Volume 2, Issue 5, pp.1041-1052, September-October-2017.