Low Harmonic Mitigation Through Fuzzified Inverter Control For Grid Connected Solar Energy System

Authors(2) :-Roopgandha, M. K. Kiran

With increasing renewable distributed generation(DG) units connected to utility power grids, deterioration of power quality at the point of common coupling (PCC) becomes a major concern. Power electronic devices in DG units generate harmonics; these harmonics along with harmonics from other nonlinear load in the system might cause excessive harmonic distortion at the PCC. In this paper, an extensive literature review is conducted focusing on harmonic mitigation techniques through advanced control methods for grid-interfacing inverter. The intend of the fuzzy logic approach is to meet high quality output, minimum THD,fast response and high robustness.

Authors and Affiliations

Roopgandha
PG Scholar, AMC Engineering College, Bangalore, Karnataka, India
M. K. Kiran
Assistant Professor, AMC Engineering College, Bangalore, Karnataka, India

Distributed-generation,harmonic-mitigation,Total harmonic distortion, power quality

[1] Xiaodong Liang Chowdhury Andalib-Bin-Karim , “Harmonic Mitigation through Advanced Control Methods for Grid- Connected Renewable Energy Sources” in Proc.IEEE 2017-PSEC-0801
[2] A. Chidurala, T. K. Saha, N. Mithulananthan, and R. C. Bansal, "Harmonic emissions in grid connected PV systems: A case study on a large scale rooftop PV site," in Proc. IEEE PES General Meeting, Conference & Exposition, 2014, pp. 1-5.
[3] X. Liang, “Emerging power quality challenges due to integration of renewable energy sources”, IEEE Trans. Industry Applications, vol. 53,no. 2, pp. 855-866, 2017.
[4] M. A. Awadallah, B. Venkatesh, and B. N. Singh, “Impact of solar panels on power quality of distribution networks and transformers”, CanadianJournal of Electrical and Computer Engineering, vol. 38, no. 1, pp. 45-51, 2015.
[5] R. K. Varma, S. A. Rahman, T. Vanderheide, and M. D. N. DANG, “Harmonic impact of a 20-MW PV solar farm on a utility distribution network”, IEEE Power and Energy Technology Systems Journal, vol. 3, no. 3, pp. 89-98, 2016.
[6]Chinnathambi Govindaraju, Kaliaperumal Baskaran,”Power Loss Minimizing control of cascaded multilevel inverter with efficient hybrid carrier based space vector modulation”, International Journal of Electrical and Computer Engineering Systems, Vol. 1, No. 1, pp 43-53, June 2010.
[7]Dr.N.Amuthan and Srikanth H.P ,”Review of IGBT Based Ultrasonic Circuits”,International Journal of Power Electronics,Vol.6,Issue 1
[8] Gounden NA, Peter SA, Nallandula H, Krithiga S (2009) Fuzzy logic controller with MPPT using line-communicated inverter for three-phase grid-connected photovoltaic systems. Renewable Energy 34:909915

Publication Details

Published in : Volume 4 | Issue 5 | March-April 2018
Date of Publication : 2018-04-14
License:  This work is licensed under a Creative Commons Attribution 4.0 International License.
Page(s) : 261-267
Manuscript Number : CSEIT184532
Publisher : Technoscience Academy

ISSN : 2456-3307

Cite This Article :

Roopgandha, M. K. Kiran, "Low Harmonic Mitigation Through Fuzzified Inverter Control For Grid Connected Solar Energy System", International Journal of Scientific Research in Computer Science, Engineering and Information Technology (IJSRCSEIT), ISSN : 2456-3307, Volume 4, Issue 5, pp.261-267, March-April-2018.
Journal URL : http://ijsrcseit.com/CSEIT184532

Article Preview

Follow Us

Contact Us