A Simplified Thermal Design Model for a Single Vertical U-Tube Borehole Utilized in Ground-Coupled Source Heat Pumps

Authors

  • Ali H. Tarrad  Professor, Ph.D. Mechanical Engineering, Université de Lorraine, CNRS, LEMTA, Nancy, France

DOI:

https://doi.org/10.32628/CSEIT206533

Keywords:

Single U-tube, Borehole Thermal Resistance, Correlation, DX Heat Exchanger, R410A

Abstract

The present work dealt with the thermal assessments of the ground-coupled heat pump heat exchangers utilized in the field of geothermal energy source. A model was performed to predict the overall thermal resistance of a single vertical heat exchanger embedded in the borehole. The philosophy of the U-tube replacement with a single equivalent tube size was implemented with new development. Four tube sizes were used to build several borehole geometry configurations, they were (9.53) mm, (12.7) mm, (15.88) mm, and (19.05) mm accommodated in borehole sizes of (65) mm, (75) mm, (90) mm, and (100) mm respectively. Twelve borehole geometry configurations were examined as DX condensers circulate R410A refrigerant. These geometry assemblies produced a range of (0.29-0.57) for tube spacing to borehole ratio tested at (0.73) W/m K to (1.9) W/m K filling thermal conductivity range. The results of the present correlation showed good agreement with previously published correlations in the open literature. A mean temperature difference between the condensed vapor refrigerant and soil was assumed to have existed as (14) °C. Increasing the tube spacing from (2) to (3) times the tube diameter exhibited an augmentation in the heat loading of the borehole. This rise in the heat loadings of the U-tube was (8-10) % and (13-17) % for the geometry configurations of (9.53) mm and (12.7) mm tube sizes respectively. The tube diameter has also shown its importance in the thermal process of the borehole. At (75) mm borehole size and tube spacing of (2) times tube outside diameter, the predicted borehole thermal resistance for (9.53) mm tube diameter was higher than that of (19.05) mm one by (78-80) % for the test range of grout thermal conductivity.

References

  1. Zeng H, Fang Z (2002) A fluid temperature model for vertical U-tube geothermal heat exchangers. Journal of Shandong Institute of Architecture and Engineering 17(1): 7-10.
  2. Zeng H, Diao N, Fang Z (2002) A finite line-source model for boreholes in geothermal heat exchangers. Heat Transfer – Asian Research 31(7): 558-567.
  3. Zanchini E, Lazzari S, Priarone A (2010) Effects of flow direction and thermal short-circuiting on the performance of small coaxial ground heat exchangers. Renewable Energy 35: 1255–1265.
  4. Zanchini E, Lazzari S, Priarone A (2010) Improving the thermal performance of coaxial borehole heat exchangers. Energy 35: 657–666.
  5. Li Z, Zheng M, (2009) Development of a numerical model for the simulation of vertical U-tube ground heat exchangers. Applied Thermal Engineering, 29(5): 920-924.
  6. Bauera D, Heidemann W, Diersch, H G (2011) Transient 3D analysis of borehole heat exchanger modeling. Geothermics 40: 250–260.
  7. Rees S J, He M (2013) A three-dimensional numerical model of borehole heat exchanger heat transfer and fluid flow. Geothermics 46: 1– 13.
  8. Song X, Lyu Z, Li G, Sheng M, Liu J, Li R, Shi Y (2017) Numerical analysis of characteristics of a single U-tube down hole heat exchanger in the geothermal reservoir. GRC Transactions 41.
  9. Yavuzturk C, Spitler J D, Rees S J (1999) A transient two-dimensional finite volume model for the simulation of vertical U-tube ground heat exchangers, ASHRAE Transactions 105(2): 465-474.
  10. Ingersoll L R, Zobel O J, Ingersoll A C (1948) Heat conduction with engineering and geological application, McGraw Hill, New York.
  11. Muttil N, Chau K W (2006) Neural network and genetic programming for modeling coastal Algal Blooms. Int. J. Environ. Pollut. 28: 223-238.
  12. Ingersoll L R, Zobel O J, Ingersoll A C (1954) Heat conduction with engineering, geological and other applications, revised edition; University of Wisconsin Press: Madison.
  13. Carslaw H S, Jaeger J C (1959) Conduction of heat in solids, 2nd ed.; Oxford University Press: London.
  14. Kavanaugh S P (1985) Simulation and experimental verification of vertical ground-coupled heat pump systems. International Journal of Energy Research, 21(8): 707-722.
  15. Claesson J, Dunand A (1983) Heat extraction from the ground by horizontal pipes- A mathematical analysis, Document D1, Swedish Council for Building Research, Stockholm.
  16. Bose J E, Parker J D, McQuiston F C (1985) Design/data manual for closed-loop ground-coupled heat pump systems. American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE): Atlanta.
  17. Shonder J A, Beck J V (1999) Determining effective soil formation thermal properties from field data using a parameter estimation technique. ASHRAE Transactions 105: 458-466.
  18. Gu Y, O’Neal D L (1998) Development of an equivalent diameter expression for vertical U-tubes used in ground-coupled heat pumps. ASHRAE Transaction 104(2), pt. (2)- 4214: 1-9.
  19. Remund C P (1999) Borehole thermal resistance: laboratory and field studies, ASHRAE Trans 105: 439–445
  20. Sharqawy M H, Mokheimer E M, Badr H M (2009) Effective pipe-to-borehole thermal resistance for vertical ground heat exchangers. Geothermics 38: 271–277.
  21. Koenig A A (2015) Thermal resistance of borehole heat exchangers composed of multiple loops and custom shapes. Geothermal Energy 3(10): 1-14.
  22. Tarrad A H (2019) A borehole thermal resistance correlation for a single vertical DX U-tube in geothermal energy application. American Journal of Environmental Science and Engineering 3(4): 75-83.
  23. Tarrad A H (2020) A perspective model for borehole thermal resistance prediction of a vertical U-tube in geothermal heat source, Athens Journal of Technology and Engineering 7(2): 73-92
  24. Tarrad A H (2020) Development of analytical model for a vertical DX single U-tube ground-coupled heat pump system. Accepted for publication in Global Journal of Researches in Engineering, J: General Engineering 20(3):1-14.
  25. Holman, J. P, 2010. Heat Transfer, 10th edition, published by McGraw-Hill, chapter 3: 83-86.
  26. Sagia Z, Stegou A, Rakopoulos C (2012) Borehole resistance and heat conduction around vertical ground heat exchangers. The Open Chemical Engineering Journal 6: 32-40.
  27. Gaia Geothermal. Ground loop design software, GLD 2009.
  28. Huang X, Ding G, Hu H, Zhu Y, Gao Y, Deng B (2010) Condensation heat transfer characteristics of R410A–oil mixture in 5 mm and 4 mm outside diameter horizontal microfin tubes. Experimental Thermal and Fluid Science 34(7): 845-856.
  29. Kim M, Shin J (2005) Condensation heat transfer of R-22 and R410A in horizontal smooth and microfin tubes. International Journal of Refrigeration 28(6): 949-957.
  30. Garbai L, Méhes S (2008) Heat capacity of vertical ground heat exchangers with single U-tube installation in the function of time. WSEAS Transactions on Heat and Mass Transfer 3(3): 177-186.

Downloads

Published

2020-10-30

Issue

Section

Research Articles

How to Cite

[1]
Ali H. Tarrad, " A Simplified Thermal Design Model for a Single Vertical U-Tube Borehole Utilized in Ground-Coupled Source Heat Pumps" International Journal of Scientific Research in Computer Science, Engineering and Information Technology(IJSRCSEIT), ISSN : 2456-3307, Volume 6, Issue 5, pp.151-162, September-October-2020. Available at doi : https://doi.org/10.32628/CSEIT206533